SZL Water Tube Quickly Installed (Assembled) Hot Water Boiler
![]() SZL Water Tube Quickly Installed (Assembled) Hot Water Boiler |
Product Description
SZL water tube quickly installed (assembled) boiler has 2 vertical steam drums, and the innovative horizontal cyclone-fired combustion chamber, which could effectively enhance the thermal efficiency and reduce the flue gas emission concentration. The flue gas emission concentration is lower than 100 mm/nm3, the flue gas blackness is lower than Ringelmann level 1, which enables the boiler to be used in the first-class environment protected area. The boiler installs one cast iron economizer at its afterbody, the fire-gate applies the chamber-segregated ventilation structure, which is easy to adjust. The separate-layer coal supply device could be chosen according to the customer requirement. Advantages of such boiler are: Strong power, high thermal efficiency, 110% override capability, compactly designed, small floor area. Customers appreciate its safely operated, investment conserved, and broadly fuel adapted capability most.
SZL series hot water boiler specification and boiler auxiliaries (as table).
Remarks:
1. The parameter in the upper sheet is only for your reference, we will not inform customer the varied size and dimension due to the design and installation;
2. The coal consumption is calculated according to the coal in bulk heat rate 6000 kcal/kg;
3. The boiler exterior size is in accordance with the design drawing.
| Model Parameter | SZL4.2-1.0/95/70-AII | SZL5.6-1.0/95/70-AII | SZL7.0-1.0/95/70-AII | SZL10.5-1.25/150/90-AII | SZL14-1.25/150/90-AII | ||
| Rated evaporation capacity | t/h | 4.2 | 5.6 | 7 | 10.5 | 14 | |
| Operation pressure | Mpa | 1 | 1 | 1 | 1.25 | 1.25 | |
| Steam temperature | ºC | 95 | 95 | 115 | 150 | 150 | |
| Water-inlet temperature | ºC | 70 | 70 | 70 | 90 | 90 | |
| Boiler heating efficiency | % | 78 | 79.6 | 78.7 | 80.8 | 81.7 | |
| Area of boiler heating surface | m2 | 154 | 175 | 234 | 471 | 578 | |
| Area of stoker | m2 | 7.15 | 8.6 | 11.72 | 16.4 | 18.9 | |
| Heating Area | m2 | 36000 | 48000 | 60000 | 90000 | 120000 | |
| Fuel | Coal available | | II type bitumite,low heat capability:17700-21000KJ/kg | ||||
| Consumption | kg/h | 900 | 1280 | 1450 | 2460 | 3240 | |
| Water entrance and exit diameter | m | Pn1.6 Dn150 | Pn1.6 Dn200 | Pn1.6 Dn150 | Pn1.6 Dn200 | Pn1.6 Dn200 | |
| Dimensions of biggest parts for shipment (L x W x H) | mm | 7.62x3.27x3.46 | 8.82x3.34x3.46 | 7.78x3.38x3.53 | 9.05x3.35x3.69 | 10.59x3.35x3.69 | |
| 8x3.5x2.7 | |||||||
| Weight of biggest parts for shipment | t | 31 | 45 | 27.2/22.3 | 24 | 27 | |
| Overall dimensions of boiler assembled (L x W x H) | m | 8.4x4.9x3.92 | 9.38x3.34x3.46 | 9.8x5.2x6 | 12.3x5.3x7.2 | 14.22x5.3x8.04 | |
| Total boiler weight | t | 36 | 48 | 74.3 | 108 | 116 | |
| Circulating water pump | model | | IS125-100-200B | IS125-100-200 | IS200-150-315 | | |
| flow | M3/H | 172 | 200 | 240 | | | |
| lift | M | 37 | 50 | 37 | | | |
| Motor power | KW | 30 | 45 | 55 | | | |
| Blower | Model | | G6-41-13 No7.1A | G6-41-13 No8.5A | G6-41-13 No6.5A | TG15-1 | TG20-1 |
| Ventilation | m3/h | 5349-10354 | 9369-18137 | 9369-18137 | 23000 | 32079 | |
| Wind pressure | Pa | 2270-1697 | 2536-3391 | 2535-3391 | 1960 | 2559 | |
| Motor Power | KW | 7.5 | 18.5 | 18.5 | 18.5 | 30 | |
| Induced draft fan | Model | | Y6-41-13 No10C | Y6-41-13 No11.2C | Y6-41-13 No11.20C | TY15-2 | TY20-2 |
| Ventilation | m3/h | 32144-16604 | 41773-21578 | 41773-21578 | 40000 | 54900 | |
| Wind pressure | Pa | 2575-3444 | 2764-3697 | 2764-3697 | 3038 | 3148 | |
| Motor Power | KW | 37 | 45 | 45 | 55 | 75 | |
| Model: | SZL |
| Company: | Qingdao Yuhe Happiness Boiler Co., Ltd. |
Other products from this company
Most Popular
-

Vacuum Phase-Transfer High Efficient Hot Exchanger Hot ... The characteristic of vacuum phase-transfer high ... -

Hot Water Boiler Burning Gas Or Oil (WNS) We are a campany enter in 20077 and mainly deal ... -

Oil Gas Fired Radiator Heating Hot Water Boiler The structure of directly heated hot water boiler ...
-

Vacuum Tube Furnaces (XD-1600MT) XD-1600MT tube furnace is a precision bench-top ... -

Vertical Oil(Gas) Fired Steam Boiler The upper blown boilers avoid the defections of ... -

Assembled Type Coal Fired Single and Binary Steel Wire ... This furnace is to use mechanical coal firing ...
-

Steam Boiler (WNS Series) WNS series of fuel (gas) steam boiler performance ... -

Biomass Pellet Stove (MS-Series) Our Pellet Stove is very beautiful and suitable ... -

Melting Furnace (VT-1T) Place of Origin: China(aminland) Brand Name: Vt ...
-

Liquid Level Switch/Level Control/Float Ball Switch (FS-02) Liquid Level Switch/Level Control/Float Ball ... -

Steel Wire Heat-Treatment Furnace (Coal) 1. Furnace type: Muffle heat-treatment furnace; ... -

Generation III Steel Wire Heat Treatment Direct-Fired ... No. Of patent: ZL69222909.1 (1). Special furnace ...
-

DZL Series Coal-Fired Boiler Compact structure, small size, transporting the ... -

Muffle Furnace (XD-1200N) Δ Operation Temperature: 1100. C ( 1200. C ... -

Electric Heating Steam Boiler (WDZ2.0-1.0) Boiler type: WDZ2.0-1.0 Nominal electric ...
Quick Products |
Inquiry Basket (



